PROJOY MC4 PEFS-EL40H-4 Fire Fuse (for 2 strings)
Specification.
-One or two independent chains can be connected.
-Three or four chains can be connected in parallel per independent input-max 40A per input up to 1000V
-Current rating up to 40A per chain.
-DC voltage up to 1500V
-CE Certificate
-Mechanical motorized disconnector
-IP66 plastic PC+ABS enclosure
-MC4 Connectors
-DC-side insulation compliant with: TUV, CE, CB, SAA, UL.
-Automatic shutdown below 70
DC voltage per string (V) 300 ~ 1500
DC voltage per string (A) 9 ~ 40
Maximum current up to 1000V 40A
Maximum current up to 12000V 30A
Maximum current up to 15000V 20A
Number of independent strings - 1 ~ 2
Number of strings connected in parallel per input 3 ~ 4 (max 40A przy 1000V)
Wiring of disconnector- 2/4S/4A at 1000V)
Operating voltage range 100 Vac - 270 Vac
Nominal voltage- 230 Vac
Nominal AC current 30mA
Starting AC current average 100mA
Current AC current on DC ON/OFF switch max 300mA
Back connection 24Vdc - 300mA
Operating temperature range -20 degrees - +50 degrees
Maximum operating temperature before automatic shutdown +70degrees
Storage temperature -40degrees - +80degrees
Protection rating IP66
Protection grade II
CE Certificate
DC disconnector compliant with EN 60947-1$3
Maximum switching capacity 10000
Maximum switching capacity under load (PV1) 1500
Technical data
| Number of strings | 2 |
| String current | 40 A |
| Nominal current | 30 mA |
| Chain voltage | 300 ~ 1500 V DC |
| Operating voltage | 100 V AC - 270 V AC |
| Nominal voltage | 230 V AC |
| Protection level [IP] | IP66 |
| Grade of protection | II |
Availability: sold out
€161.82
Net price: €131.56
PROJOY MC4 fire fuse PEFS-EL50H-6 (for 3 strings)
The series features the following:
- Switches suitable for 1,2,3,4 5 strings - depending on model
- up to 85 A
- up to 1500 V DC
- CE certification
- Motor protection circuit breaker
- Robust plastic housing IP66
- holes | cable connectors | MC4 contacts in place
- Integrated DC isolator with TUV, CE, CB, SAA, UL, CCC certification
- Automatic switch-off at 70ºC
- fitted with a breather valve to avoid condensation inside the housing
Specifications:
- Series and type: Fire safety switch 3 strings for photovoltaic systems PV PEFS-EL50H-6 3MPPT PROJOY
- Chain voltage (Vdc): 300 ~ 1500 V DC
- String current (A): 50 A
- Number of strings: 3
- Wiring switch: 6
- Operating voltage: 100 V AC - 270 V AC
- Nominal voltage: 230 V AC
- Nominal current: 30 mA
- Starting current: average 100 mA
- Power on/off switch: max. 300 mA
- Back connection : 24 V DC - 300 mA max.
- Operating temperature range: -20ºC - + 50ºC
- Maximum operating temperature before automatic shutdown: + 70ºC
- Storage temperature range: -40ºC - + 85ºC
- Protection rating: IP66
- Protection grade: II
- Certificates: CE
- DC disconnector disconnected according to: EN 60947-1&3
- Maximum switching capacity: 10000
- Maximum switching capacity under load (PV1): >1500
Data
| Number of strings | 3 |
| String current | 50 A |
| Nominal current | 30 mA |
| Chain voltage | 300 ~ 1500 V DC |
| Operating voltage | 100 V AC - 270 V AC |
| Nominal voltage | 230 V AC |
| Protection rating [IP] | IP66 |
| Grade of protection | II |
Availability: sold out
€257.86
Net price: €209.64
PROJOY MC4 fire fuse PEFS-EL40H-10 (for 5 strings)
Technical Specification:
- Series and type: Fire safety switch 5 strings for photovoltaic installations PV PEFS-EL40H-10 5MPPT PROJOY
- Chain voltage (Vdc): 300 ~ 1500 V DC
- String current (A): 40 A
- Number of strings: 5
- Wiring switch: 10
- Operating voltage: 100 V AC - 270 V AC
- Nominal voltage: 230 V AC
- Nominal current: 30 mA
- Starting current: average 100 mA
- Power on/off switch: max. 300 mA
- Back connection : 24 V DC - 300 mA max.
- Operating temperature range: -20ºC - + 50ºC
- Maximum operating temperature before automatic shutdown: + 70ºC
- Storage temperature range: -40ºC - + 85ºC
- Protection rating: IP66
- Protection class: II
- Certificate: CE
- DC disconnector disconnected in accordance with: EN 60947-1&3
- Maximum switching capacity: 10000
- Maximum switching capacity under load (PV1): >1500
Key features of the series:
- Switches suitable for 1,2,3,4, 5 strings - depending on model
- up to 85 A
- up to 1500 V DC
- CE certificates
- Mechanical motorized disconnector
- Robust plastic housing IP66
- holes | cable connectors | MC4 contacts in place
- Integrated DC isolator with TUV, CE, CB, SAA, UL, CCC certification
- Automatic switch-off at 70ºC
- fitted with a breather valve to avoid condensation inside the housing
For the current over 40A, select cable glands or overcurrents.
Data
| Number of strings | 5 |
| String current | 40 A |
| Nominal voltage | 30 mA |
| Chain voltage | 300 ~ 1500 V DC |
| Operating voltage | 100 V AC - 270 V AC |
| Nominal voltage | 230 V AC |
| Protection rating [IP] | IP66 |
| Grade of protection | II |
Availability: sold out